Get
/catalog/api/v1/inverters/{compatibility}/mine/private-only
Security
API Key: ApiKeyAuth
Header parameter nameX-API-Key
Path parameters
compatibility
stringRequired
Valid values[
"sgis",
"pvsyst",
"iec",
"cec",
"pvcc"
]
Query parameters
name
string
manufacturer
string
manufacturerIds
string
Comma(,) separated ids of manufacturers
nMppTrackers
string
Number of MPP trackers
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
nDcInputsPerMpp
string
Number of DC inputs per MPPT
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
maxAcPwr
string
Maximum AC power “rating” for inverter at reference or nominal operating condition, assumed to be an upper limit value
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
nOutputAcPhases
string
Number of AC phases
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
maxOperatingDcVoltage
string
Maximum DC voltage at which an inverter is able to operate at reduced power.
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
nominalAcVoltage
string
Nominal output voltage
Expected format:
- Values in range from-to $number--$number e.g. 0--100, -5--100, -100---5
- Values greater than $number-- e.g. -5--, 0--, 100--
- Values less than --$number e.g. ---5, --0, --100
Pattern^(-?\d*\.?\d+|\s*)--(-?\d*\.?\d+|\s*)$
sortColumn
string
Valid values[
"name",
"max_ac_pwr",
"manufacturer"
]
sortOrder
string
Valid values[
"asc",
"desc"
]
rating
string
X=0, C=10, B=20, A=30, A+=40. Comma (,) separated.
confidenceClass
string
X=0, C=10, B=20, A=30, A+=40. Comma (,) separated.
perPage
number
Minimum1
Maximum100
Default10
currentPage
number
Minimum1
Default1
Responses
200
List of inverters compatible with the given compatibility level
object
data
Array
OneOf
SgisInverter
object (SgisInverter)
id
string
Paco
number
Vdcmin
number
Vopermax
number
Vdcmax
number
Idcmax
number
Vdco
number
Pnt
number
nMppTrackers
number
Vac
number
nOutputAcPhases
number
Pdco
number
Pso
number
C0
number
C1
number
C2
number
C3
number
Vdclow
number
Vdcmedium
number
Vdchigh
number
Vmppmin
number
Vmppmax
number
Width
number
Height
number
Depth
number
Weight
number
name
string
manufacturer
string
maxEfficiency
number
euroEfficiency
number
cecEfficiency
number
nDcInputsPerMppTracker
number
cosPhiLag
number
cosPhiLead
number
nightPwrConsumption
number
Iacmax
number
attachmentsCount
number
rating
number
Default0
confidenceClass
number
Default0
status
string
Valid values[
"CONCEPT",
"VALIDATED",
"REVIEW_PENDING",
"REVIEW_IN_PROGRESS",
"REVIEW_APPROVED",
"REVIEW_REJECTED",
"PUBLISHED",
"ARCHIVED",
"EXPIRED"
]
IecInverter
object (IecInverter)
id
string (uuid)
VARtg
number | null
InvCTlSrc
string | null
ClMthTyp
string | null
InAMax
number | null
AvarMaxRtg
number | null
WRtg
number | null
VMaxRtg
number | null
VMinRtg
number | null
VArRtg
number | null
IvarMaxRtg
number | null
InVMax
number | null
AMaxRtg
number | null
VAMaxRtg
number | null
VRtg
number | null
WMaxRtg
number | null
rating
number
Default0
confidenceClass
number
Default0
CecInverter
object (CecInverter)
id
string (uuid)
Name
string | null
CEC_Type
string | null
CEC_hybrid
boolean | null
Idcmax
number | null
Vdcmax
number | null
Mppt_high
number | null
Mppt_low
number | null
CEC_Date
string | null
Pnt
number | null
Pso
number | null
Paco
number | null
Vac
number | null
Pdco
number | null
Vdco
number | null
C0
number | null
C1
number | null
C2
number | null
C3
number | null
rating
number
Default0
confidenceClass
number
Default0
PvsystInverter
object (PvsystInverter)
id
string
Comment
string | null
ParObj1
number | null
Version
string | null
PVObject_Commercial
object
Manufacturer
string | null
Comment
string | null
Model
string | null
YearBeg
number | null
MarketOUT
string | null
DataSource
string | null
Depth
number | null
Height
number | null
Width
number | null
Weight
number | null
Converter
object
EfficEuro
number | null
EfficEuroV
Array of number
Min items3
Max items3
number | null
EfficMax
number | null
EfficMaxV
Array of number
Min items3
Max items3
number | null
VNomEff
Array of number
Min items3
Max items3
number | null
NPtsMax
number | null
NPtsEff
number | null
ModeOper
string | null
IDCMax
number | null
VAbsMax
number | null
VMPPMax
number | null
VMppMin
number | null
PSeuil
number | null
VmppNom
number | null
CompPMax
string | null
CompVMax
string | null
TPLim1
number | null
PLim1
number | null
PLimAbs
number | null
TPLimAbs
number | null
TPMax
number | null
TPNom
number | null
IMaxAC
number | null
PMaxOUT
number | null
INomAC
number | null
VOutConv
number | null
MonoTri
string | null
PNomConv
number | null
FResNorm
number | null
NbInputs
number | null
NbMPPT
number | null
AC_Switch
string | null
DC_Switch
string | null
TanPhiMax
number | null
TanPhiMin
number | null
DiscAdjust
string | null
MS_Thresh
number | null
Night_Loss
number | null
rating
number
Default0
confidenceClass
number
Default0
pagination
object
total
number
currentPage
number
lastPage
number
perPage
number
from
number
to
number
401
API Key is missing or invalid
object
message
string